Showing results: 16 - 30 of 105 items found.
-
APCIE-1564-5V-HS -
TEAM SOLUTIONS, INC.
32 digital inputs, 5 V, isolated16 interruptible inputs32 digital outputs, 5 V, isolated, 10 to 36 V, 500 mA/channelOptical isolation 1000 VWatchdog for resetting the outputs to "0" (when Power-On)Protection against fast transients, overvoltage, electrostatic discharge and high-frequency EMIInputs: voltage reversal, input filtersOutputs protected against short circuitOvertemperature and overvoltage protectionDiagnostic report in case of short circuits, overtemperature, voltage drop ...24 V power outputs with protection diodesShutdown logic when the external supply voltage drops below 5 V
-
76600 -
Hickok Inc.
High visibility, simple to use, one handed dynamic voltage testing. Indicates Power and Grounds. Test the circuit's ability to deliver current and identify loose, corroded or broken wires. Capture intermittent spikes or drops in voltage. Take Voltage Snapshots in any mode, any time.
-
CX-L19 -
Shenzhen Chuangxin Instruments Co., Ltd.
It applied with rectangle size of platinum electrode, each electrode can force to the sample is 1.0±0.05N. Electrode Distance: 4.0mm±0.01mm, included angle: 60°±5°. Electrode Voltage: 100~600V, (48~60HZ) adjustable, when the short-circuit current at 1.0±0.1A, the voltage goes down less than 10%. The liquid drop device can make the liquid height from 30~40mm (adjustable), drops liquid size is 44~55 drops/1cm3. The interval drops of liquid is 30s±5s (adjustable). During the testing, the short-circuit current is more than 0.5A to keep 2 seconds, then shut off current, it show the sample not pass. Inside dimension: 0.5CBM and outside dimension: 630mm*390mm*750mm.
-
YAV90075 -
6TL Engineering
This module is ideal to cover power supply needs in fixture proyects. For voltages up to 20V, through two regulable channels. With an minimum input level of 2.7V and a maximum of 20V, has only 340mV of drop voltage. The maximum current supplied for each channel is 1.5A.
-
Osborne Transformer Corp.
Osborne DC filter inductors (aka filter chokes) are commonly used in AC to DC conversion circuits to present an inductive voltage drop to the AC component of rectified current. This inductive voltage drop acts as a filter. Osborne designs filter inductors to components to function effectively (without saturation) in the presence of the DC current. Osborne will work with you to mitigate the impact of ripple frequency in conversion circuits. Every Osborne DC filter choke is designed for high performance with special consideration given to your circuit´s power supply frequency and conversion configuration.
-
Avtech Electrosystems, Ltd.
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
M-2100 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Conform to IEC safety requirements.
-
88-PRO -
Laurel Electronics, Inc
The 88-PRO Process Meter may be connected directly to a 4-20 mA, 10-50 mA or 1-5 mA current loop, with no need for additional power to the meter. This is because the meter is powered directly by the current loop, developing a maximum voltage drop of 2.5 V.
-
AUTO DIAGNOSTECH LTD
We invented the “Resistance method” which uses a series of shorting pulse to measure the voltage drop in order to calculate the plate’s internal resistance. Unlike other patented “Conductance method” which generates an AC pulse across the battery terminal to measure impedance.
-
5658 -
Abaco Systems Inc
ECM P/N 5658 provides eight channels of 16 bit current measurement in the 0 to 25 milli-amp range. Each channel allows independent common mode voltages from -100 volts to +100 volts. Current detection is accomplished with a precision 100 ohm current sense resistor, creating a voltage drop of 2V in the current loop at 20 milli-amps.
-
Modbus RS485 -
Catnip Electronics
This is a contact-less capacitive soil moisture sensor, a continuation of my I2C soil moisture sensor. This particular version of the sensor is suited for more professional installations where long cable runs is a requirement. It adds a local voltage regulator to mitigate the voltage drop and RS485 transceiver to accommodate long wires, also reverse polarity and an additional ESD protection level is added.
-
62000P -
Chroma Systems Solutions, Inc.
Chroma’s Programmable DC Power Supplies 62000P Series offer many unique advantages for ATE integration and testing. Advantages include: constant power operating envelope, precision readback of output current and voltage, output trigger signals as well as the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations.
-
M-260 -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Wide current measurements with tear drop type 55mmφCT up to 2000A.*Data-hold and Auto power off function.*Additional AC/DC voltage, resistance, diode test, continuity check.*Auto zero adjustment for DC current offset.*Conform to IEC safety requirements.
-
CFIA-40 4 -
Chuan Sheng Electronics Co., Ltd.
1. Using LED to display, and able to be used in dark environment2. No external power needed3. Able to display measured value like pressure , temperature and depth etc4. Display solution 1/99995. Isolated alarm open drain output6. Voltage drop will below 4 volt
-
Technology Products
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.